Figure 9a

Figure 9b

MAINTENANCE(CONT)

How To Prevent Damage From Freezing Temperatures

To prevent damage from freezing temperatures follow this procedure:

1.Use the vacuum hose to remove all the solution from the clean solution tank.

2.Connect the solution hose to the extractor and a floor tool.

3.Put approximately 1 quart of antifreeze solution in the solution tank.

4.Put the switch for the pump in the "ON" position.

5.Put the end of the floor tool in the recovery pail.

6.Press the lever on the floor tool to activate the pump.

7.Make sure the solution runs through the system.

8.Release the lever on the floor tool to stop the pump.

9.Flush the antifreeze solution from the system before using the extractor.

WARNING: Electrical repairs must be done by authorized personnel only.

WARNING: After electrical repairs are done to the machine, the machine must be tested for electrical safety.

How To Get Access To The Pump and Vacuum Motor

To get access to the pump and the vacuum motor, follow this procedure (see figures 9a & 9b):

1.Empty both tanks.

2.Unlatch tanks from base.

3.Tilt tanks back.

4.Disconnect hoses from tanks.

5.Open up for service.

Page 26

Clarke® BEXT® -100, 100H 150H, 300HV Operator's Manual