OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

1

9

2

3

4

5

6

7

8

General Parts Drawing

ITEM #

DESCRIPTION

FUNCTION

1.

Tilting Handle

Used for tilting the kettle.

2.

Vacuum/Pressure Gauge

Indicate steam pressure in PSI inside steam jacket as well as

 

 

vacuum in inches of mercury.

3.

Pressure Relief Valve

This valve is used to vent the kettle and in the unlikely event there is

 

 

an excess steam build-up in the jacket, this valve opens

 

 

automatically to relieve this pressure.

4.

Heat Indicator Light (Green)

When lit, indicates that the kettle's burner is on.

 

 

Cycles ON-OFF with burner.

5.

Low Water Indicator Light (Red)

When lit, indicates that the kettle is low on water and will not operate

 

 

in this condition (see Reservoir Fill Procedures).

6.

Ignition Failure Indicator Light

Indicates failure of heating system to ignite.

 

(Amber)

 

7.

On-Off Switch/

Turns kettle ON/OFF and allows the operator to adjust the kettle

 

Solid State Temperature

temperature in increments from 1 (Min.) to 10 (Max.).

 

Control

(see Temperature Range Chart in the Operating Instructions

 

 

section).

8.

Marine Lock

Prevents unit from accidental tilting.

9.

Water Level Sight Glass

Displays water level in steam jacket.