ELECTRIC

ELECTRIC WATER QUALITY REQUIREMENT

Each compartment has capacity for:

Eight,

12˝ x 20˝ x 212˝

Cafeteria Pans or

Six,

12˝ x 20˝ x 4˝

Cafeteria Pans or

Four,

12˝ x 20˝ x 6˝

Cafeteria Pans or

Four,

18˝ x 26˝

Bun Pans

Many regional, state and local codes exist and it is

the responsibility of the owner and installer to com- ply with those codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, NSF, ASME/N.Bd., CSA.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows:

TOTAL DISSOLVED SOLIDS less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.

WATER

DRAINAGE D

CLEARANCE

KW Volts Watts Ph Amps Wire

24208 21,500 1 103.4 2

220 24,000 1 109.1 2

240 24,000 1 100.0 2

440 20,200 1 45.9 2

480 24,000 1 50.0 2

208 21,500 3 59.7 3

220 24,000 3 63.1 3

240 24,000 3 57.8 3

440 20,200 3 26.5 3

480 24,000 3 28.9 3

600 24,000 3 23.1 3

360 21,500 3 34.5 4

380 24,000 3 36.5 4

415 24,000 3 33.4 4

KW Volts Watts Ph Amps Wire

36

208

32,200

3

89.5

3

 

 

220

36,000

3

94.6

3

 

 

240

36,000

3

86.7

3

 

 

440

30,200

3

39.7

3

 

 

480

36,000

3

43.4

3

 

 

600

36,000

3

34.7

3

 

 

360

32,200

3

51.7

4

 

 

380

36,000

3

54.8

4

 

 

415

36,000

3

50.1

4

 

48

208

42,900

3

119.2

3

 

 

220

48,000

3

126.1

3

 

 

240

48,000

3

115.6

3

 

 

440

40,300

3

52.9

3

 

 

480

48,000

3

57.8

3

 

 

600

48,000

3

46.2

3

 

 

360

42,900

3

68.9

4

 

 

380

48,000

3

73.0

4

 

 

415

48,000

3

66.9

4

1/4˝ NPT

The Floor Drain must be located

Right - 3”, Left - 3”,

Cold Water Inlet

outside the confines of the

Rear - 3” (12” on control

35 psi minimum

equipment base.

side if adjoining wall or

 

equipment is over 30” high

60 psi maximum

1 1/2˝ I.P.S. common drain.

for service access)

Do not connect other units to this

 

Contact factory for

 

drain.

 

Do not use PVC pipe for drain.

variances to clearances.

(NOT TO SCALE) SECT. VI PAGE 2 0707