ELECTRIC
•Each compartment has capacity for:
Eight, | 12˝ x 20˝ x 21⁄2˝ | Cafeteria Pans or |
Six, | 12˝ x 20˝ x 4˝ | Cafeteria Pans or |
Four, | 12˝ x 20˝ x 6˝ | Cafeteria Pans or |
Four, | 18˝ x 26˝ | Bun Pans |
•Many regional, state and local codes exist and it is
the responsibility of the owner and installer to com- ply with those codes.
•Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, NSF, ASME/N.Bd., CSA.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY | less than 20 parts per million |
SILICA | less than 13 parts per million |
pH FACTOR | greater than 7.5 |
CHLORINE | less than 30 parts per million |
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
WATER | DRAINAGE D | CLEARANCE |
KW Volts Watts Ph Amps Wire
24208 21,500 1 103.4 2
220 24,000 1 109.1 2
240 24,000 1 100.0 2
440 20,200 1 45.9 2
480 24,000 1 50.0 2
208 21,500 3 59.7 3
220 24,000 3 63.1 3
240 24,000 3 57.8 3
440 20,200 3 26.5 3
480 24,000 3 28.9 3
600 24,000 3 23.1 3
360 21,500 3 34.5 4
380 24,000 3 36.5 4
415 24,000 3 33.4 4
KW Volts Watts Ph Amps Wire
36 | 208 | 32,200 | 3 | 89.5 | 3 | |
|
| 220 | 36,000 | 3 | 94.6 | 3 |
|
| 240 | 36,000 | 3 | 86.7 | 3 |
|
| 440 | 30,200 | 3 | 39.7 | 3 |
|
| 480 | 36,000 | 3 | 43.4 | 3 |
|
| 600 | 36,000 | 3 | 34.7 | 3 |
|
| 360 | 32,200 | 3 | 51.7 | 4 |
|
| 380 | 36,000 | 3 | 54.8 | 4 |
|
| 415 | 36,000 | 3 | 50.1 | 4 |
| 48 | 208 | 42,900 | 3 | 119.2 | 3 |
|
| 220 | 48,000 | 3 | 126.1 | 3 |
|
| 240 | 48,000 | 3 | 115.6 | 3 |
|
| 440 | 40,300 | 3 | 52.9 | 3 |
|
| 480 | 48,000 | 3 | 57.8 | 3 |
|
| 600 | 48,000 | 3 | 46.2 | 3 |
|
| 360 | 42,900 | 3 | 68.9 | 4 |
|
| 380 | 48,000 | 3 | 73.0 | 4 |
|
| 415 | 48,000 | 3 | 66.9 | 4 |
1/4˝ NPT | The Floor Drain must be located | Right - 3”, Left - 3”, | |
Cold Water Inlet | outside the confines of the | Rear - 3” (12” on control | |
35 psi minimum | equipment base. | side if adjoining wall or | |
| equipment is over 30” high | ||
60 psi maximum | 1 1/2˝ I.P.S. common drain. | ||
for service access) | |||
Do not connect other units to this | |||
| Contact factory for | ||
| drain. | ||
| Do not use PVC pipe for drain. | variances to clearances. |
(NOT TO SCALE) SECT. VI PAGE 2 0707
Cleveland Range reserves right of design improvement or modification, as warranted.