Troubleshooting / User Maintenance (Continued)
Reduced spray or no spray. (Continued)
Possible Cause
6.The Pump Belt may be broken.
Lift Here
Insert
Screwdriver
Blade Here
Remedies
6.Turn the machine OFF (O) and unplug from the outlet. To check if a Pump Belt has broken, you will need a flat head screwdriver. Insert the blade end into the lower slot of the Belt Access door to release the lower snap. If necessary, insert the blade end into the upper slot to release the upper snap. Examine the belt for breakage. You should be able to see the Pump Belt looped around the motor shaft. If it is broken or missing, please refer to Replacement Parts on page 19 before calling Consumer Services. Complete installation instructions will accompany the replacement belt.
DirtLifter PowerBrush does not turn.
Possible Cause | Remedies |
1.The Brush Belt or Pump Belt is off or broken.
1.Turn the machine OFF (O) and unplug from the outlet. To check if the Brush Belt or Pump Belt has broken, you will need a flat head screwdriver. Insert the blade end into the lower slot of the Belt Access door to release the lower snap. If necessary, insert the blade end into the upper slot to release the upper snap. Examine the belt for breakage. If broken, please refer to Replacement Parts on page 19 before calling Consumer Services. Complete installation instructions will accompany the replacement belt.
Carpet Protector is not spraying. (Select Models Only)
Possible Cause
1.Cartridge not connected to the tool.
2.Solution clogging the Spray Trigger.
3.Applicator tool spray is blocked.
Remedies
1.Follow instructions on cartridge assuring proper fit.2.Soak applicator tool in hot water. Spray without the cartridge attached to purge any residual Solution left in the tool.
3.Soak applicator tool in hot
water. Spray without the cartridge attached to purge any residual Solution left in the tool.
w w w . b i s s e l l . c o m
8 0 0 . 2 3 7 . 7 6 9 1 | 17 |