SEQUENCE OF OPERATIONS

SEQUENCE OF OPERATIONS

When using these instructions refer to the SEL-TI wiring schematic.

1.Supply Voltage is sent to the primary of the 120 VAC transformer.

2.Supply voltage is sent to the normally open con- tacts of the Heat Contactors, C 1 and C2.

3.120 VAC is sent from the secondary of the 120VAC transformer through the 3 amp fuse to

The primary of the 24 VAC transformer

24 VAC is sent from the secondary of the 24VAC transformer through the 1.25 amp fuse to the on/off switch.

Contacts of the R1 Heat Relay

4.120 VAC is sent from the secondary of the 120 VAC transformer to the optional Power Tilt Circuit (See step 9).

5.With the On/Off switch in the On position.

24 VAC is sent through the normally closed high limit switch to the mercury switch..

If the skillet is in the down position then 24 VAC is sent through mercury switch to pin 9 on the ther- mostat.

6.If the steamer is calling for heat the 24 VAC is sent from pin number 10 to RI Heat Relay.

The normally open contacts of the Heat relay close sending 120 VAC to the Heat contactor coils C 1 and C2.

7.The Contactor close and supply Voltage is sent to the elements.

The elements heat until the thermostat is satis- fied.

8.When thermostat is satisfied, 24 VAC is removed from pin 10 on the thermostat and the heat circuit is de-energized.

9.If the skillet has the optional Power Tilt option and is in the down position, 120 VAC is sent from the secondary of the 120 VAC transformer through the circuit breaker and the up limit switch to the tilt switch.

10.With the tilt switch in switch in the Up position

120 VAC is sent to the Bridge Rectifier

115 VDC is sent from the rectifier through the 30-ohm resistor to the normally open RY10 and RYI I relay contacts.

120 VAC is sent to the RY10 relay coil.

The normally open RY10 contact close and 90 VDC is sent to the DC motor

The DC motor is energized and the skillet tilts until the switch is released or the up limit switch opens.

11.With the Tilt switch in the Down position

120 VAC is sent to the Bridge Rectifier

115 DC is sent from the rectifier through the

30-ohm resistor to the normally open RY 10 and RY 11 relay contacts.

120 VAC is sent to the RY11 relay coil.

The normally open RY 11 contact close and the polarity of the 90 VDC is reversed.

The DC motor is energized and the skillet lowers until the switch is released or

POWER TILT MANUAL OVER- RIDE

In case of power failure or malfunction the skillet pan can be tilted manually following these instructions.

MANUAL

TILT

SHAFT

10 MM

6POINT POWER TILT MANUAL OVER- RIDE SOCKET

1.Fit a 10 MM 6 POINT SOCKET over the MANUAL TILT SHAFT as shown above.

2.Turn socket wrench clockwise to empty contents.