Place connect jumper #1

SHOWS WIRE CONNECTIONS PIN 1, PIN 2, AND GROUND (PIN 6).

7.For the adapter to output data for RS485, a jumper inside the metal case must be positioned correctly. This photo shows the position of the #1 jumper. All other jumpers should be in the original position.

Place connect jumper #1

Jumper #1 Position

8.Place the metal cover back on the adapter and secure the screws.

9.The adapter is now ready for use with the PC-HACCP.