Instructions

Instructions

3. Installation

3.1.Electrical*

A 15 Amp, 240 Volt, 60 Hz dedicated circuit should be used to supply electrical power to the GL-C machine (see specification sheet page 2). The power connection with the leads L-1,L-2 and Ground must be such that there is sufficient length of flexible conduit to permit the machine to be moved for cleaning. This machine operates from 208 to 240 Volts.

3.2.Plumbing*

Hot Water Connection

1.Connect a minimum 1/2” water line to the hot water solenoid valve. Supply temperature must be minimum 140°F/60°C,with flow pressure between 25-95 PSI.

2.Hot water consumption is approximately 12 U.S. gph.

Cold Water Connection

1.Connect a minimum 1/2” water line to the cold water solenoid valve. Flow pressure must be between 25-95 PSI.

2.Open ball valve located between hot and cold solenoid valves until temperature reaches 75°F for areas with very cold rinse water to heat the rinse water which will prevent glasses from cracking.

3.Cold water consumption is approximately 2.8 U.S. gpm.

Drain Connection

1.Connect a 1-1/2” drain line where indicated.

2.PVC pipe is generally recommended, as copper is prone to attack by the sanitizing chemicals.

*Electrical and plumbing connections must be made by a qualified person who will comply with all available Federal, State, and Local Health, Electrical, Plumbing and Safety codes.

MODEL GL-C Installation & Operation Manual Rev. 1.00A –2/23/06

Page 4

Page 5
Image 5
CMA Dishmachines MODEL GL-C Instructions, Installation, Electrical, Plumbing, Hot Water Connection, Cold Water Connection