Operation
5.Operation
5.1.Filling the Wash Tank
•Ensure that the overflow drain tube is in place in the detergent tank.
•Flip power
•The water temperature is controlled by a heater and a thermostat .The thermostat should be set for minimum 140°F/60°C.
5.2.Operating Instructions
•Open the door; flip power
•Ensure there is product in the detergent, sanitizer and rinse agent containers.
•Detergent is fed from the supply container into the detergent tank in controlled amounts by the detergent pump. Use detergent at strength recommended by your chemical supplier.
•Load glasses on the conveyor. Start machine with
3.2.1.Proper Chemical Dosage
The amount of chemical delivered, whether it is detergent, sanitizer or rinse aid, can be obtained by counting the revolutions of the injector rotors.
•For detergent, contact your chemical supplier for proper type and detergent concentration. Note: Detergent pump only operates when hot water tank is filling.
•For sanitizer, one revolution in 5 seconds equals approximately 12.5ppm Iodine or 50ppm chlorine.
•For rinse agent, one revolution in 8 seconds is recommended.
To Adjust Detergent Injector:
•When a new detergent container is installed, push the prime button in and hold until the detergent feed tube is full.
•Install the overflow drain tube and switch power
•To increase detergent volume, turn the detergent adjustment screw clockwise.
•To decrease the detergent volume, turn the detergent adjustment screw
To Adjust Sanitizer Injector:
•When a new sanitizer container is installed, push the prime button in and hold until sanitizer feed tube is full.
•Start the washer with rocker switch located on the front of the machine. Take a sample from the final rinse spray tube to check sanitizer level.
•To increase the volume of sanitizer, turn the adjustment screw clockwise.
•To decrease the volume of sanitizer, turn the adjustment screw
To turn rinse agent injector “OFF” in this case, turn the adjustment screw
Note: If a sodium Hypochlorite (Chlorine) based sanitizer at a minimum concentration of 50ppm in the final rinse is used, use chlorine test papers to verify and monitor the 50ppm chlorine level
MODEL | Page 6 |