Operation
To Adjust Rinse Agent Injector:
•When a new rinse agent container is installed, push the prime button in and hold until the rinse injector feed tube is full.
•Start the washer. Take a sample from the final rinse spray tubes.
•To increase the volume of rinse agent, turn the adjustment screw clockwise.
•To decrease the volume of rinse agent, turn the adjustment screw
Note:To meet the requirements of N.S.F. standards, Iodophor in a concentration of 12.5ppm or chlorine at 50ppm must be used in the final rinse.
5.3.Cleaning Instructions
3.3.1. Daily Cleaning Instructions
Remove optional
Remove right and left trays and
Remove the conveyor as follows: Remove conveyor hub, flip conveyor
Remove lower wash and rinse arms. Clean wash and rinse areas with hot soapy water. Rinse thoroughly, and then dry.
Note: Do not twist spray arms, pull straight out or they will break.
Replace lower wash and rinse arms (they only fit one way). Replace conveyor as follows: With back end of conveyor raised, mesh drive gear with side of conveyor, pull conveyor towards you until center of conveyor drops onto pivot. Replace conveyor hub in center of conveyor, flip
Remove and clean upper and lower wash tank screens.
Remove overflow drain tube from the detergent tank, wash down the interior of the detergent tank. Replace overflow drain tube and upper and lower wash tank screens.
Note: Do not leave water in tank overnight!!!
Replace optional
Ensure there is product in the detergent, sanitizer and rinse agent containers. Close the door.
3.3.2. Weekly Cleaning Instructions
Remove upper and lower wash and rinse arms from the manifold and clean spray tubes with Cleaning Drill p/n 00899.01, Cleaning Brush p/n 00899.02 provided.
Remove detergent, sanitizer, and rinse agent feed lines from containers and place them in a container of hot water. Hold prime buttons in until the feed lines have been thoroughly flushed. Replace the feed lines to their proper container and prime product through lines.
MODEL | Page 7 |