CMA Dishmachines MODEL GL-C manual Maintenance, Troubleshooting

Models: MODEL GL-C

1 11
Download 11 pages 62.51 Kb
Page 9
Image 9
Maintenance

Maintenance

6.Maintenance

6.1. Troubleshooting

PROBLEM

LIKELY CAUSE

SOLUTION

Conveyor doesn’t turn

Power off at circuit breaker

Reset circuit breaker

 

Drive motor burn out

Replace drive motor

 

 

 

 

Obstruction in wash or rinse

Remove obstruction

 

Micro switch on switch support

Replace or adjust

 

bracket faulty or not making

 

 

contact

 

 

Conveyor not in position

Position properly

Excessive overspray from

Splash curtain not in position

Install or adjust

hood section

 

 

Washer running without any

Keep conveyor loaded with

 

 

glasses on conveyor

glasses

 

Spray tubes fallen off hub

Ensure spray tube is pushed

 

 

firmly on to hub connection

 

Spray tubes plugged

Clear and clean with reamer,

 

 

scraper, and brush

Lack of pressure in wash

No water in detergent tank

Ensure water supply is on

spray tubes

 

Ensure detergent tank stand

 

 

pipe is in position

 

 

Ensure the tank fill switch is in

 

 

On-Fill position and that tank

 

 

fills with water

 

 

Ensure the float switch is

 

 

activated by the float cam

 

 

Ensure the tank fill solenoid is

 

 

operational

 

Obstruction in wash arm

Clear obstruction

 

 

 

 

Pump not operating

Check power supply to

 

 

machine

 

 

Check pump capacitor

 

 

Replace pump if required

 

 

 

 

Pump operating but no pressure

Check condition of impeller

 

 

and stub shaft

 

 

Replace if needed

Lack of pressure in rinse

Rinse spray tubes dirty

Clean thoroughly with reamer,

spray tube

 

scraper, and brush provided

 

Shut-off valve on supply line

Open valve

 

closed

 

 

Low water pressure

Minimum 25PSI flow pressure

 

 

required

MODEL GL-C Installation & Operation Manual Rev. 1.00 –2/23/06