QuickSpecs

HP ProLiant DL585 Generation 2 (G2)

Standard Features

Expansion Slots

 

 

Expansion

Technology

Width

Connector

Bus

Form Factor

Notes

 

 

Slot #

 

 

Width*

Number**

 

 

 

 

 

1

PCI-X

64-bit

N/A

42h

FH/HL

100MHz

 

 

2

PCI-X

64-bit

N/A

42h

FH/FL

100MHz

 

 

3

PCI Express

x4

x8

49h

FH/FL

 

 

 

 

4

PCI Express

x4

x8

4Ch

FH/FL

 

 

 

 

5

PCI Express

x8

x16

46h

FH/FL

 

 

 

 

6

PCI Express

x4

x8

4Fh

FH/FL

 

 

 

 

7

PCI Express

x8

x16

02h

FH/FL

 

 

 

 

8

PCI Express

x8

x16

05h

FH/FL

 

 

 

 

9

PCI Express

x4

x8

08h

FH/HL

Reserved for

 

 

 

 

 

 

 

 

storage

 

 

 

 

 

 

 

 

controller

 

 

* Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.

 

 

** Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest Device ID

 

 

by bus (starting with the lowest bus).

 

 

 

 

 

 

 

FH = Full height; FL = Full length; HL = half-length; LP = Low profile.

 

 

 

 

Manageability

Integrated Lights-Out 2 (iLO 2) Standard Management (ASIC on the System Board)

 

 

 

 

 

 

 

 

 

 

 

 

Storage Controllers One of the following depending on Model

HP Smart Array P400/256MB Controller (in a PCI-Express slot) NOTE: Standard on 2.0GHz and 2.2GHz models.

HP Smart Array P400/512MB BBWC Controller (in a PCI-Express slot) NOTE: Standard on 2.4GHz, 2.6GHz, 2.8GHz, and 3.0GHz models.

Storage Data Protection The Battery-Backed Write Cache (BBWC) Enabler for the Smart Array P400 Controller protects up to 512-MB write cache memory from hard boot, power, controller, or system board failures.

Standard on all HP ProLiant DL585 G2 Models

Battery charge/life: Up to 72 hours/3 years

Transportable data protection

Increases overall controller performance

NOTE: Safely transport your write cache data to another HP ProLiant DL585 G2 in the data center by removing the BBWC Enabler and Smart Array P400 Controller Memory Module simultaneously (connected by short cable).

DA - 12575 Canada — Version 37 — May 28, 2008

Page 4

Page 4
Image 4
Compaq DL585 G2 manual Width Connector Bus, Manageability