QuickSpecs
HP ProLiant DL585 Generation 2 (G2)
Technical Specifications
| System Unit | Dimensions (H x W x D) | 6.94 x 19 x 26.5 in (17.6 x 48.3 x 67.3 cm) | ||
| 
 | (with bezel) | 
 | 
 | 
 | 
| 
 | Weight | Maximum | 95 lb (43 kg) | |
| 
 | (approximate) | (all hard drives, power | 
 | 
 | 
| 
 | 
 | supplies, and processors | 
 | 
 | 
| 
 | 
 | installed) | 
 | 
 | 
| 
 | 
 | Minimum | 79 lb (36 kg) | |
| 
 | 
 | (one hard drive, power | 
 | 
 | 
| 
 | 
 | supply, and processor | 
 | 
 | 
| 
 | 
 | installed) | 
 | 
 | 
| 
 | Input Requirements | Rated Line Voltage | 90 - 132 VAC, | |
| 
 | (per power supply) | 
 | 180 - 264 VAC | |
| 
 | 
 | Rated Input Current | 12 A (at 100 VAC), | |
| 
 | 
 | 
 | 8 A (at 200 VAC) | |
| 
 | 
 | Rated Input Frequency | 47 to 63 Hz | |
| 
 | 
 | Rated Input Power | 1161 | W (at 100 VAC), | 
| 
 | 
 | 
 | 1598 | W (at 200 VAC) | 
| 
 | BTU Rating | Maximum | 3985 | BTU/hr (at 100 VAC), | 
| 
 | 
 | 
 | 5457 | BTU/hr (at 200 VAC) | 
Power Specifications To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL: http://h30099.www3.hp.com/configurator/calc/Power%20 Calculator%20Catalog.xls
Click on the system of interest. Example: DL585 G2
Follow the instructions of the next screens
| Power Supply Output (per | Rated  | 910 W (at 100 VAC), | 
| power supply) | 
 | 1300 W (at 200 VAC) | 
| 
 | Maximum Peak Power | 960 W (at 100 VAC), | 
| 
 | 
 | 1420 W (at 200 VAC) | 
| System Inlet Temperature | Operating | 10° to 35°C (50° to 95°F) at sea level with an | 
| 
 | 
 | altitude derating of 1.0°C per every 305 m | 
| 
 | 
 | (1.8°F per every 1000 ft) above sea level to a | 
| 
 | 
 | maximum of 3050 m (10,000 ft), no direct | 
| 
 | 
 | sustained sunlight. Maximum rate of change is | 
| 
 | 
 | 10°C/hr (18°F/hr). The upper limit may be | 
| 
 | 
 | limited by the type and number of options | 
| 
 | 
 | installed. | 
| 
 | 
 | System performance may be reduced if | 
| 
 | 
 | operating with a fan fault or above 30°C (86°F). | 
| 
 | ||
| 
 | 
 | change is 20°C/hr (36°F/hr). | 
| Relative Humidity | Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) | 
| 
 | maximum wet bulb temperature, non- | |
| 
 | 
 | condensing. | 
| 
 | 5 to 95% relative humidity (Rh), 38.7°C | |
| 
 | 
 | (101.7°F) maximum wet bulb temperature, non- | 
| 
 | 
 | condensing. | 
| 
 | 
 | 
 | 
| DA - 12575 Canada — Version 37 — May 28, 2008 | Page 41 | 