QuickSpecs

HP ProLiant DL585 Generation 2 (G2)

Technical Specifications

System Unit

Dimensions (H x W x D)

6.94 x 19 x 26.5 in (17.6 x 48.3 x 67.3 cm)

 

(with bezel)

 

 

 

 

Weight

Maximum

95 lb (43 kg)

 

(approximate)

(all hard drives, power

 

 

 

 

supplies, and processors

 

 

 

 

installed)

 

 

 

 

Minimum

79 lb (36 kg)

 

 

(one hard drive, power

 

 

 

 

supply, and processor

 

 

 

 

installed)

 

 

 

Input Requirements

Rated Line Voltage

90 - 132 VAC,

 

(per power supply)

 

180 - 264 VAC

 

 

Rated Input Current

12 A (at 100 VAC),

 

 

 

8 A (at 200 VAC)

 

 

Rated Input Frequency

47 to 63 Hz

 

 

Rated Input Power

1161

W (at 100 VAC),

 

 

 

1598

W (at 200 VAC)

 

BTU Rating

Maximum

3985

BTU/hr (at 100 VAC),

 

 

 

5457

BTU/hr (at 200 VAC)

Power Specifications To review typical system power ratings use the Power Calculator which is

available via the online tool located at URL: http://h30099.www3.hp.com/configurator/calc/Power%20 Calculator%20Catalog.xls

Click on the system of interest. Example: DL585 G2

Follow the instructions of the next screens

Power Supply Output (per

Rated Steady-State Power

910 W (at 100 VAC),

power supply)

 

1300 W (at 200 VAC)

 

Maximum Peak Power

960 W (at 100 VAC),

 

 

1420 W (at 200 VAC)

System Inlet Temperature

Operating

10° to 35°C (50° to 95°F) at sea level with an

 

 

altitude derating of 1.0°C per every 305 m

 

 

(1.8°F per every 1000 ft) above sea level to a

 

 

maximum of 3050 m (10,000 ft), no direct

 

 

sustained sunlight. Maximum rate of change is

 

 

10°C/hr (18°F/hr). The upper limit may be

 

 

limited by the type and number of options

 

 

installed.

 

 

System performance may be reduced if

 

 

operating with a fan fault or above 30°C (86°F).

 

Non-operating

-30° to 60°C (-22° to 140°F). Maximum rate of

 

 

change is 20°C/hr (36°F/hr).

Relative Humidity

Operating

10 to 90% relative humidity (Rh), 28°C (82.4°F)

(non-condensing)

 

maximum wet bulb temperature, non-

 

 

condensing.

 

Non-operating

5 to 95% relative humidity (Rh), 38.7°C

 

 

(101.7°F) maximum wet bulb temperature, non-

 

 

condensing.

 

 

 

DA - 12575 Canada — Version 37 — May 28, 2008

Page 41

Page 41
Image 41
Compaq DL585 G2 manual Technical Specifications