DIGITAL-LOGIC AG

SMA200 Manual V1.0

5.4.7.SMBus

 

 

 

 

On Module

Ext. Ter-

Max.

 

Matched

Signal

BUS

Type

Description

Termination

mination

Length

Ohm

Length

 

 

 

 

 

Needed

in mm

 

in mm

SMB_ALERT#

CMOS

3.3V

Connect to the SMB device

PU 10k to

-

200

55

-

 

 

In

 

3.3V

 

 

 

 

SMB_DATA

CMOS

3.3V

Connect to the SMB device

PU 4.7k to

-

200

55

-

 

 

I/O

open drain

3.3V

 

 

 

 

SMB_CLOCK

CMOS

3.3V

Connect to the SMB device

PU 4.7k to

-

200

55

-

 

 

I/O

open drain

3.3V

 

 

 

 

If the signals are not used:

The pins can stay open.

Remarks:

The SMB_ALERT# may be used to initiate an SMB event over APIC or an SMI.

Maximum BUS capacitance is 200pF. For higher BUS loads, the SMB repeater PCA9515 from Philips is recommended. Each new SMB segment must be terminated with 2x 4.7k.

EMV/EMI filters:

Are not needed.

31

Page 31
Image 31