3-16 l Installation
Testing the Installation (continued)
7Adjust the setpoint to the desired hopper inlet temperature. Use the
Setpoint Adjust ▲or ▼buttons to set the temperature. Move the heater enable
switch to the enable position. The temperature should stabilize around the set-
point and not significantly overshoot the set temperature.
8If everything is working properly,the heater’s LED flashes and the tem-
perature climbs towards the setpoint.
For Carousel Plus Dryers
5Reference the dryer manual and verify the dryer’s blower is running in the
correct direction and the dryer is ready for operation.
6Start the dryer.
7Adjust the setpoint to the desired hopper inlet temperature. Use the
Setpoint Adjust ▲or ▼buttons to set the temperature. Move the heater enable
switch to the enable position. The temperature should stabilize around the set-
point and not significantly overshoot the set temperature.
8If everything is working properly,the heater’s LED flashes and the tem-
perature climbs towards the setpoint.
Heaters
Startup /
Shutdown
For Startup:
1. With heaters in
Standby, turn on
blower or dryer.
2. Enable heaters.
For Shutdown:
1. Switch heaters to
Standby.
2. Wait 60 seconds
before turning off
blower or dryer.
Enable
Standby
Setpoint Adjust
Buttons