Start-up
1Using the Start/Stop button, ”Jog" the motor
to check for proper wheel rotation. The motor
should be started in accordance with the manufac-
turer's recommendations. Arrows on the fan indi-
cate the proper direction of rotation and airflow.
2Throttle the blower discharge
damper ¼ open. (It is shown
fully open in this photo.)
3The fan may now be brought
up to speed. Watch for anything
unusual such as vibration, over-
heating of bearings and motor,
etc.
4Throttle the discharge damper until the pressure is 15-20" WC.
5Check the motor amperage against the nameplate amperageto
make sure the motor is not overloading.
Addendum l AD-5
Start/Stop
Button
Discharge
Damper
Fully Closed
Fully Open