Connect Tech JB2, JB0, JB1 Appendices - RS-485/422 Interface, Technical Tip, Titan/cPCI adapter

Models: JB0 JB2 JB3 JB1

1 36
Download 36 pages 25.13 Kb
Page 34
Image 34
4-14 Chapter 4: Appendices – RS-485/422 Interface

4-14 Chapter 4: Appendices – RS-485/422 Interface

Figure 6 describes a 2 wire cabling scheme between a port on the Titan/cPCI adapter to a port on the RS-485/422 peripheral.

Figure 6: RS-485/422 wiring diagram (2 wire)

Titan/cPCI adapter

RS-485 peripheral

1

RxD +

TxD +

 

 

3

TxD +

RxD +

 

 

4

TxD -

RxD -

 

 

2

RxD -

TxD -

 

 

7

RTS +

CTS +

 

 

8

CTS +

RTS +

 

 

9

RTS -

CTS -

 

 

6

CTS -

RTS -

 

 

5

SR

SR

 

 

Technical Tip

The RS-485/422 electrical interface consists of a differential signaling scheme. You should always connect the signals with twisted pairs