Chapter 4: Appendix E - 20mA Current Loop Option |
Current Loop Cable Wiring
You can wire the ACM/Flex16 with the 20mA Current Loop option in various ways to communicate with 20mA Current Loop peripherals. This section describes an example of a Current Loop cabling scheme.
Figure 22 describes a 4 wire cabling scheme between a port on the ACM/Flex16 and another port on an external device.
Figure 22: Current Loop wiring diagram(4 wire)
External
Current
Source
+-
TxD + | 2 |
|
| RxD - |
TxD - | 7 |
|
| RxD + |
RxD - | 1 |
|
| TxD + |
RxD + | 8 |
|
| TxD - |
ACM/Flex16 Port | + | - | External Device | |
Connector | ||||
|
| External |
| |
|
| Current |
| |
|
| Source |
|
|
Note:
The example above illustrates a 20mA Current Loop cable wiring configuration between one port of the ACM/Flex16 and another port of an external device.