STOVE VENT CONNECTION
11
MOBILE HOME INSTALLATION
1.Attach the ad- justable pipe to the last section of rigid piping. Se-
cure with screws 2" OVERLAP and seal.
2.Install the 4" aluminum flexible liner to the stove. Secure with 3 screws and flat washers. Seal the joint and screw holes using Mill Pac high tem- perature sealant not supplied.
FIGURE 21
#8x1/2"
SELF DRILLING SCREWS
SEALANT
In Canada, mobile home installation may be vented hori- zontally or vertically. In the United States, it may only be installed vertically. See "Vertical Venting" or "Horizontal Air Terminal Installation" for installation.
The | fireplace is |
equipped with | |
two | 5/16" |
d i a m e t e r | |
holes located | |
near | each |
corner of the base. For mo- bile home in- s t a l l a t i o n s , the fireplace must be fas-
3. Run a bead of | " | 1 | 4 |
|
|
|
| /4 |
|
|
| ||
red RTV high tem- |
| - |
|
| ||
3 |
|
| 5/ |
| ||
| - |
|
|
| 3 | 2 |
perature sealant | 5 |
|
|
|
| " |
|
|
|
|
| ||
|
|
|
|
|
|
around the inside of the air intake
collar. Pull the adjustable pipe a minimum 2" into the air intake collar.
Ensure that the sealant is not visible on the exte- rior pipes once installation is completed. An op- tional decorative brass band is available for this use. (Standard with a GD175 kit). In the event that the venting must be disassembled, care must be taken to reseal the venting.
tened in place. Use #10 screws, inserted through the holes in the base to secure. It is recommended that the fireplace be secured in all installations.