REPLACEMENT BLOWER INSTALLATION

19

REPLACEMENT BLOWER INSTALLATION

FIGURE 45

FIGURE 44

1.Turn off the electrical power and the gas supply to the stove.

2.Open the lower louvre control door, the two side doors, and the fire viewing door. Remove the logs.

3.Remove the relief door held on with 6 screws. Discard the gasket.

4.Disconnect the two blower wires. Remove the blower bracket held on with 4 screws.

5.Replace the blower using the existing bracket. When connecting the replacement blower, tighten the screws with- out distorting the rubber grommets. Replace the bracket/ blower assembly on the unit.

6.Reconnect the two wires. Hold the replacement gasket in place and reattach the relief door body. Replace the logs. Close all doors.

7.Turn the gas supply and electricity back on.

Because the blower is thermally activated, when turned on, it will automatically start approximately 15-30 min- utes after lighting the stove and will run for approximately 30-45 minutes after the stove has been turned off. Use of the fan increases the output of heat.

Drywall dust will penetrate into the blower bearings caus- ing irreparable damage and must be prevented from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.