FIGURE 4
CONDENSATE EVAPORATOR INSTALLATION
REMOVAL OF DOORS AND DOOR ADJUSTMENT
During installation, it may become necessary to remove the cabinet doors to facilitate passage through narrow doorways or hallways. To remove a door, pry off all hinge covers using a sharp tool or knife (see figure 5). Swing the door to the
All doors have been aligned at the factory, however vibration during transportation may cause doors to shift and realignment may be necessary. If the door(s)
require realignment, proceed as follows:
1.Pry off all hinge covers using a sharp tool or knife.
2.For each door, loosen the screws which secure the hinge bodies to the cabinet face and slide the door into alignment. Hold the door firmly in place and tighten all screws securely.
If the door gasket(s) do not seal properly to the cabinet face and there are gaps between the gasket and the face on the hinge edge, proceed as follows:
1.For each door, loosen all screws which are directed into the edge of the door and push the door towards the cabinet eliminating the gap. Hold the door firmly in place and tighten all screws securely.
2.Replace all