FIGURE 7

compressor is not operating during an off-cycle. Do not set the thermostat too cold where the cabinet temperature will fall below 2`c because the evaporator will become blocked by ice since the compressor off-cycle will be considerably shortened. This will result in loss of product stored within the cabinet and require service to defrost the evaporator and re-adjust the thermostat.

FIGURE 7

REFRIGERATOR AND FREEZER THERMOSTAT

FREEZER SYSTEM AND ADJUSTMENT

All self-contained standard freezers and low-temperature freezers are designed and factory set to maintain an average cabinet temperature of -20`c and -28`c respectively. All freezers are designed for the purpose of holding pre-frozen bulk product and although they are capable of freezing small quantities of non-frozen product, they are not to be used as fast or blast freezers. Do not attempt to freeze bulk quantities of product. The temperature control is accessible from the top of the electrical console box located on the cabinet top behind the front grill (see figure 6).if an adjustment is necessary to maintain the above temperature range only on standard freezers, place a screwdriver into the thermostat slot and turn clockwise for a colder cabinet temperature or counterclockwise for a warmer