the condensing unit is
SPECIAL VOLTAGE CONNECTIONS
When models are ordered from the factory with special, optional voltages, connections should be made as required on the electrical wiring diagram provided on the upper cabinet end panel next to the electrical console box.
START-UP CHECKLIST
After your model has been installed, leveled, cleaned, and electrically connected in accordance with this manual, please take the time before
1.Check that all exposed refrigeration lines are free of severe dents or kinks.
2.Check the condenser fan and evaporator fans for freedom to rotate without any obstructions
3.Make sure that the cabinet is properly leveled (see "leveling" under installation and location section).
The system should run smoothly and quietly in accordance with generally accepted commercial standards. If any unusual noises are heard, turn the unit off immediately and check for any obstructions of the condenser or evaporator fans. Fan motors, fan blades, or fan housings can be jarred out of position through rough handling in transit or during installation.
Important Note: All freezer models have an
Caution: If unit is unplugged or disconnected for any reason, allow several minutes
REMOTE APPLICATIONS
All models are available for purchase as remote models in which case the condensing unit is purchased separately and installed at the time of installation. All remote models are equipped with an expansion valve located within the evaporator coil housing, and both liquid and suction lines stubbed and extending out from the cabinet case top behind the front grill. Installation of the refrigeration accessories,
- 10 -