BrickFuses

1025FA Series, Fast Acting

Description

Surface Mount

Environmentally rugged, satisfies the EIA/IS-722 Standard

Solder Immersion Compatible

Targeted for Consumer Electronics

ELECTRICAL CHARACTERISTICS

% of Amp Rating

 

Opening Time

100%

4 Hours Minimum

200% (250mA-5A)

5 Seconds Maximum

250% (250mA-5A fuse)

1

Second Maximum

200% (7A-15A fuse)

20

Seconds Maximum

250% (7A-15A fuse)

4 Seconds Maximum

Dimensions mm(inches)

Drawing Not to Scale

Note: 30vde constant current source required for 200% overload tests on 250ma-1a.

Agency Information

UL Recognition Guide & File numbers: JDYX2 & E19180 (250mA - 15A)

CSA Component Acceptance:

File # 053787 C000, Class # 1422 30

Environmental Data

Life Test: MIL-STD-202, Method 108A, Test Condition D

Load Humidity: MIL-STD-202, Method 103B

Moisture Resistance: MIL-STD-202, Method 106E

Terminal Strength: MIL-STD-202, Method 211A

Thermal Shock: MIL-STD-202, Method 107D, air-to-air

Case Resistance: EIA/IS-722

Resistance to Dissolution of Metallization: ANSI J-STD-002, Test D

Mechanical Shock: MIL-STD-202, Method 213B with exceptions per EIA/IS-722 Standard

High Frequency Vibration: MIL-STD-202, Method 204D, Test Condition D

Resistance to Solvents: MIL-STD-202, Method 215A

Land Pattern

3.30

(0.130)

4.38

(0.172)

6.79

(0.267)

Soldering Method

Wave Solder: 260°C, 10 sec max.

Infrared Reflow: 260°C, 30 sec max.

Ordering

• Specify product code and packaging code

SPECIFICATIONS

 

Voltage

 

Interrupting

 

DC Cold

Typical

Typical

Marking

Product Code

Rating

 

 

Rating*

 

Resistance** (ohms)

Melting

Voltage

Code‡‡

 

AC

DC

250VAC 125VDC 60VDC

Typical

I2t†

Drop‡

1st & 2nd 3rd

1025FA250mA

250V

125V

50A

 

50A

 

-

5.0000

0.1212

2019 mV

AD

 

1025FA500mA

250V

125V

50A

 

50A

 

-

1.2000

0.0415

1500 mV

AF

 

1025FA750mA

250V

125V

50A

 

50A

 

-

0.6000

0.143

880 mV

AG

 

1025FA1A

250V

125V

50A

 

50A

 

-

0.3000

1.750

560 mV

AH

 

1025FA1.5A

250V

125V

50A

 

50A

 

-

0.1040

1.460

260 mV

AK

 

1025FA2A

250V

125V

50A

 

50A

 

-

0.0800

6.086

258 mV

AN

U,

1025FA2.5A

250V

125V

50A

 

50A

 

-

0.0510

8.48

232 mV

AO

 

 

T

1025FA3A

250V

125V

50A

 

50A

 

-

0.0390

18.15

205 mV

AP

 

 

or

1025FA3.5A

250V

125V

50A

 

50A

 

-

0.0300

17.83

185 mV

AR

 

 

S

1025FA4A

250V

125V

50A

 

50A

 

-

0.0270

23.32

190 mV

AS

 

 

 

1025FA5A

250V

125V

50A

 

50A

 

-

0.0200

38.74

180 mV

AT

 

1025FA7A

250V

60V

50A

 

50A

 

-

0.0116

138

150 mV

AU

 

1025FA10A

250V

60V

50A

 

50A

 

-

0.0076

457

146 mV

AW

 

1025FA12A

250V

60V

50A

 

-

 

50A

0.0550

498

120 mV

AX

 

1025FA15A

250V

60V

50A

 

-

 

50A

0.0041

1451

110 mV

AY

 

*AC Interrupting Rating (Measured at designated voltage, 100% power factor random closing); DC Interrupting Rating (Measured at designated voltage, time constant of less than 50 microseconds, battery source)

**DC Cold Resistance (Measured at 10% of rated current)

T ypical Melting I2t (Measured with a battery bank at rated DC voltage, 10x-rated current, but not exceeding the interrupting rating. Time constant of calibrated circuit less than 50 microseconds). Test current not to exceed interrupting rating of 50A.

T ypical Voltage Drop (Measured at rated current after temperature stabilizes) ‡‡ Marking Code - 3 rd (U = USA, T = Taiwan and S = China)

• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures.

Page 11
Image 11
Cooper Bussmann 6125TD dimensions 1025FA Series, Fast Acting