5.7 Surge Specifications

 

 

 

 

 

 

 

 

 

 

a) TCP 500mA tested to surge requirements listed below

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Waveform

 

 

 

 

Performance

 

 

Surge Specification

Surge

Repetitions

(Sec.)

 

Current (A)

Voltage (V)

Requirement

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Longitudinal

 

 

 

 

 

 

 

 

 

 

FCC 47 Part 68

Type B

2

5x320

 

 

37.5

N/A

Fuse cannot open

 

 

 

Metallic

 

 

 

 

 

 

 

Fuse must open

 

 

FCC 47 Part 68

Type A

2

10x560

 

 

100

800

safely

 

 

Surge Out

 

25

10x160

 

 

65

N/A

Fuse cannot open

 

b) TCP1.25A and TCP2A tested to surge specifications listed below

 

 

 

Waveform

 

 

Performance

Surge Specification

Surge

Repetitions

( Sec.)

Current (A)

Voltage (V)

Requirements

FCC 47 Part 68

Longitudinal Type A

2

10x160

100 per fuse

1500

Fuse cannot open

FCC 47 Part 68

Metallic Type B

2

10x560

100

800

Fuse cannot open

Bellcore GR-1089-CORE

First Level Lighting

50

10x1000

100

1000

Fuse cannot open

Bellcore GR-1089-CORE

First Level Lighting

50

2x10

500

2500

Fuse cannot open

Surge Out

 

1

10x160

160

N/A

Fuse cannot open

Surge Out

 

1

10x560

115

N/A

Fuse cannot open

5.8 Maximum Temperature Rise (Measured at rated current after temperature stabilizes)

Catalog Symbol

M aximum Temperature Rise

TCP500mA

< 75

°C (135°F)

TCP1.25A

<

75

°C (135°F)

TCP2A

<

75

°C (135°F)

This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.