Cooper Bussmann 6125TD dimensions 1025TD Series, Time Delay

Models: 6125TD

1 32
Download 32 pages 37.56 Kb
Page 13
Image 13

BrickFuses

1025TD Series, Time Delay

Description

Surface Mount

Environmentally rugged, satisfies the EIA/IS-722 Standard

Solder Immersion Compatible

Targeted for Consumer Electronics

ELECTRICAL CHARACTERISTICS

% of Amp Rating

Opening Time

100%

4 Hours Minimum

200%

1 Second Minimum

200%

60 Seconds Maximum

250% *

10 Seconds Maximum

Dimensions mm(inches)

Drawing Not to Scale

*If fuse does not open @ 200% in 60 seconds, raise current to 250% and the fuse must open in 10 seconds maximum.

Agency Information

UL Recognition Guide & File numbers: JDYX2 & E19180 (250mA - 5A)

CSA Component Acceptance:

File # 053787 C000, Class # 1422 30

Environmental Data

Life Test: MIL-STD-202, Method 108A, Test Condition D

Load Humidity: MIL-STD-202, Method 103B

Moisture Resistance: MIL-STD-202, Method 106E

Terminal Strength: MIL-STD-202, Method 211A

Thermal Shock: MIL-STD-202, Method 107D, air-to-air

Case Resistance: EIA/IS-722

Resistance to Dissolution of Metallization: ANSI J-STD-002, Test D

Mechanical Shock: MIL-STD-202, Method 213B with exceptions per EIA/IS-722 Standard

High Frequency Vibration: MIL-STD-202, Method 204D, Test Condition D

Resistance to Solvents: MIL-STD-202, Method 215A

Land Pattern

3.30

(0.130)

4.38

(0.172)

6.79

(0.267)

Ordering

• Specify product code and packaging code

Soldering Method

Wave Immersion: 260°C, 10 sec max.

Infrared: 260°C, 30 sec max.

SPECIFICATIONS

 

Voltage

Interrupting

DC Cold

Typical

Typical

Marking

Product Code

Rating

Rating*

Resistance** (ohms)

Melting

Voltage

Code‡‡

 

AC

DC

250VAC

125VDC

Typical

I2t†

Drop‡

1st & 2nd

3rd

1025TD250mA

250V

125V

50A

50A

4.200

0.128

1900 mV

DD

 

1025TD500mA

250V

125V

50A

50A

0.5500

1.47

455 mV

DF

 

1025TD750mA

250V

125V

50A

50A

0.317

0.93

400 mV

DG

 

1025TD1A

250V

125V

50A

50A

0.2030

9.91

387 mV

DH

U,

1025TD1.5A

250V

125V

50A

50A

0.1025

11.79

310 mV

DK

T

1025TD2A

250V

125V

50A

50A

0.0680

17.27

250 mV

DN

or

1025TD2.5A

250V

125V

50A

50A

0.0420

16.51

201 mV

DO

S

1025TD3A

250V

125V

50A

50A

0.0330

42.74

184 mV

DP

 

1025TD3.5A

250V

125V

50A

50A

0.0270

43.33

180 mV

DR

 

1025TD4A

250V

125V

50A

50A

0.0220

66.96

152 mV

DS

 

1025TD5A

250V

125V

50A

50A

0.0160

88.38

145 mV

DT

 

*AC Interrupting Rating (Measured at designated voltage, 100% power factor random closing); DC Interrupting Rating (Measured at designated voltage, time constant of the calibrated circuit is less than 50 microseconds, battery source)

**DC Cold Resistance (Measured at 10% of rated current)

† T ypical Melting I2t (Measured with a battery bank at rated DC voltage, 10x-rated current, time constant of calibrated circuit less than 50 microseconds)

T ypical Voltage Drop (Measured at rated current after temperature stabilizes) ‡‡ Marking Code - 3 rd (U = USA, T = Taiwan and S = China)

• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures.

Page 13
Image 13
Cooper Bussmann 6125TD dimensions 1025TD Series, Time Delay