>Timer >

>>Form Feed Time Out 030sec.

Timer (Timer setting)

This specifies timer-related settings such as the automatic form-feed timeout and the timeout settings for Auto Sleep.

The options available in Timer are as follows:

Form Feed Time Out (Automatic form feed timeout setting)

Sleep Timer (Sleep timer timeout time)

Auto Error Clear (Auto error clear setting)

Error Clear Timer (Setting the error clear time)

Auto Panel Reset (Auto panel reset settings)

Panel Reset Timer (Setting the panel reset timer)

Auto Sleep (Setting the sleep timer)

1Press Z while Device Common > is displayed.

2Press U or V repeatedly until >Timer > appears.

Form Feed Time Out (Automatic form feed timeout setting)

If the printer receives no data for a certain period, it will time out and release the current interface. It prints whatever data it has in its buffer and feeds out the page. The default form feed timeout time is 30 seconds.

1Press Z while >Timer > is displayed.

2Press U or V repeatedly until >>Form Feed Time Out appears.

3Press [OK]. A blinking cursor (_) appears.

4Press U or V to increase or decrease the value at the blinking cursor and set the desired time. The timeout time can be between 5 and 495 seconds, in 5-second increments. Use Y and Z to move the cursor right and left.

5Press [OK].

6Press [MENU]. The display returns to Ready.

Using the Operation Panel

6-55

Page 146
Image 146
Kyocera FS-C5100DN, FS-C5300DN, FS-C5200DN manual Timer Form Feed Time Out 030sec, Timer Timer setting