TCPSeries

Telecom Circuit Protector

Description

The first and most reliable surface mount telecom circuit protector designed to protect against power cross faults and comply with all surge requirements.

Allows compliance with telecom regulatory standards including Bellcore GR 1089, UL 1950/60950, and FCC part

68.Application circuit testing is recommended.

Eliminates the need for a current limiting resistor.

Protects against overcurrent conditions found in telecom tip and ring applications.

RoHS Compliant version available (-R option)

ELECTRICAL CHARACTERISTICS

% of Amp Rating

Opening Time

100%

4 Hours Minimum

250%

1 Second Minimum

250%

4-10 Seconds Typical

250%*

120 Seconds Maximum

300%

10 Seconds Maximum

*If the device does not open at 250% within 120 seconds, increase current to 300% of amp rating. Device must open in 10 seconds max.

Agency Information

UL Recognition Card: JDYX2/E19180

CSA Component Certification Record and Class No.: 053787C000, 1422 30

Environmental Data

• Life Test: MIL-STD-202, Method 108A, Test Condition D

• Load Humidity: MIL-STD-202, Method 103B

• Moisture Resistance: MIL-STD-202, Method 106E

Thermal Shock: MIL-STD-202, Method 107D, air-to-air

Case Resistance: EIA/IS-722

Dimensions mm(inches)

Land Pattern

5.23.7

(0.204) (0.145)

4.0

(0.157)

12.6

(0.496)

• Resistance to Dissolution of Metallization:

ANSI J-STD-002, Test D

• Mechanical Shock: MIL-STD-202, Method 213B, Test

Condition A

• High Frequency Vibration: MIL-STD-202, Method 204D,

Test Condition D

• Resistance to Solvents: MIL-STD-202, Method 215A

Soldering Method

Wave Immersion: 260°C, 3 sec max.

Infrared: 240°C, 30 sec max.

LIGHTNING SURGE SPECIFICATIONS

Surge Specification

Surge

Repetitions

Waveform

Current (A)

Voltage (V)

Performance

 

 

 

(µSec.)

 

 

Requirement

 

 

TCP 500mA tested

 

 

 

FCC 47 Part 68

Longitudinal Type B

2

5x320

37.5

N/A

Fuse cannot open

FCC 47 Part 68

Metallic Type A

2

10x560

100

800

Fuse must open safely

Surge out

 

25

10x160

65

N/A

Fuse cannot open

 

 

TCP 1.25A and TCP2A tested

 

 

FCC 47 Part 68

Longitudinal Type A

2

10x160

100 per fuse

1500

Fuse cannot open

FCC 47 Part 68

Metallic Type B

2

10x560

100

800

Fuse cannot open

Bellcore GR-1089-CORE

First Level Lightning

50

10x1000

100

1000

Fuse cannot open

Bellcore GR-1089-CORE

First Level Lightning

50

2x10

500

2500

Fuse cannot open

Surge out

 

1

10x160

160

N/A

Fuse cannot open

Surge out

 

1

10x560

115

N/A

Fuse cannot open

ELECTRICAL AND POWER CROSS SPECIFICATIONS

Product

Voltage

Interrupting

 

DC Cold

 

Typical

Maximum

Typical

Alpha Code

Code

Rating

Rating*

Resistance** (ohms)

Melting

Total

Voltage

Marking

 

AC

250VAC

600VAC

min.

 

typ.

max.

I2t†

Clearing

Drop‡

1st Code

2nd Code

TCP500mA

250 V

50 A

40 A

0.420

 

0.530

 

0.640

1.3 A2s

100 A2s

471mV

F

R***

TCP1.25A

250 V

50 A

60 A

0.070

 

0.090

 

0.110

22.2 A2s

100 A2s

150mV

J

TCP2A

250 V

50 A

60 A

0.050

 

0.075

 

0.100

30 A2s

100 A2s

205mV

N

 

*AC Interrupting Rating (Measured at designated voltage, 100% power factor)

**DC Cold Resistance (Measured at 10% of rated current)

***On RoHS Compliant Version (-R option)

T ypical Melting I2t (Measured with a battery bank at 60V DC, 10x-rated current, time constant of calibrated circuit less than 50 microseconds)

T ypical Voltage Drop (Measured at rated current after temperature stabilizes)

Page 3
Image 3
Cooper Bussmann 6125TD dimensions Telecom Circuit Protector, Requirement