Water Flow Device Test Kit Installation Instructions

INSTALLATION INSTRUCTIONS

WATER FLOW DEVICE TEST KIT

The water flow device is used to determine if adequate water supply is available to support the machines that are connected to them. The device is equipped with a quarter turn ball shut off valve and a blank flare cap that permits the determination of Static Water Pressure (not flowing). In addition, there are three orifice flare caps used to determine the Water Flow Rate and Pressure.

FIGURE 1

FIGURE 2

 

Connection:

Shut off water coming from the back room. Connect the water supply line using the applicable adapter fitting (not supplied) to the 1/2” ID pigtail on the water flow device. Turn off ¼ turn valve before turning on the back room water supply. After connected, proceed with the following.

Static Pressure Check:

Place the flare gasket and blank flare cap on the device. Open ¼ turn valve and read pressure gauge. If pressure reads below 25 PSIG there is no need to go any further. Correct the supply problem before proceeding. If the pressure exceeds 60 PSIG we recommend a water pressure regulator be installed.

Flowing Pressure Check:

Estimate the water usage of all equipment connected to the water delivery system (e.g. IntelliCarb = 125 GPH, a two flavor Pinnacle = 100 GPH, Total = 225 GPH). Select the Number 3 (13/64”) orifice to insure that it can supply more than the 225 GPH required to operate both units.

Close the ¼ turn valve and remove the blank flare cap. Install the flare cap with the proper size orifice to match the flow rate desired and open the ¼ turn valve. Direct the water flow in to a large container, sink, or floor drain for at least 20 seconds. Read the pressure gauge while the water is flowing. If the gauge maintains 25 PSIG or higher, the water supply is sufficient for the flow rate that was selected.

 

Part Number

Stamp Number

Orifice Diameter

Flow Rate in Gallons Per

 

 

Hour (GPH) at 25 PSIG

 

 

 

 

 

 

 

 

 

 

 

 

 

620718954

1

1/8”

100 GPH

 

 

 

 

 

 

 

 

620718955

2

3/16”

200 GPH

 

 

 

 

 

 

 

 

620718956

3

13/64”

300 GPH

 

 

 

 

 

 

 

Release Date: August 23, 2004

www.cornelius.com

Revision: A

© 2004, IMI Cornelius Inc.

 

- 1 -

Publication Number: 629088461INS

Page 1
Image 1
Cornelius 620718955, 620718956 installation instructions Installation Instructions, Connection, Static Pressure Check

620718956, 620718954, 620718955 specifications

The Cornelius series, numbered 620718955, 620718956, and 620718954, represents a significant advancement in industrial technology, providing innovative solutions for various sectors, including manufacturing, logistics, and automation. These models have been designed to optimize efficiency, enhance productivity, and ensure sustainability in operations.

One of the standout features of the Cornelius series is its modular design. This allows for easy customization according to specific operational requirements, making it adaptable for a variety of industries. The flexibility of the Cornelius models means that users can quickly scale their systems up or down, accommodating shifts in production demands without significant downtime or investment.

Advanced technologies integrated into the Cornelius series set these models apart from their competitors. For instance, they incorporate IoT (Internet of Things) capabilities, enabling real-time monitoring and data collection. This connectivity allows businesses to analyze performance metrics, track operational efficiency, and make informed decisions. Users can access this data through a user-friendly interface, facilitating seamless operation management and troubleshooting processes.

Energy efficiency is a prominent characteristic of the Cornelius 620718955, 620718956, and 620718954 models. Equipped with state-of-the-art energy management systems, these units significantly reduce power consumption while maintaining optimal performance levels. This aligns with the growing demand for sustainable practices in industry, helping organizations lower their carbon footprint and operational costs.

Safety features are also crucial in the Cornelius series. Each model is built with enhanced safety protocols, including automatic shutdown systems, emergency stop buttons, and comprehensive safety guards. This attention to safety not only protects the equipment but also ensures the well-being of operators, creating a secure work environment.

Furthermore, the Cornelius models offer seamless integration with existing systems. Through compatibility with various software and hardware, companies can incorporate these systems into their current workflows without major overhauls. This ease of integration is highly valued in fast-paced environments where time and resources are critical.

In conclusion, the Cornelius 620718955, 620718956, and 620718954 models epitomize modern industrial solutions. With their modular design, advanced technologies, energy efficiency, robust safety features, and seamless integration capabilities, they are poised to support businesses in achieving enhanced productivity and sustainability in today's competitive landscape.