INSTALLATION

INSTALLATION

The following parts are supplied:

1Camclosure integrated camera system

1Watertight mounting plate

11/8-inch pin-in-hex Allen wrench bit

3 10-32 x 0.5-inch Phillips screws 3 #10 internal tooth lock washers

1Hole plug

PREPARE MOUNTING SURFACE

1.Remove the cover of the ICS200. Use the screwdriver bit that is provided to loosen the three tamperproof screws, and then lift the cover from the base.

2.Remove the camera module from the base: remove the Phillips screw on each side of the camera assembly and unplug the electrical connectors. Refer to Figure 1.

CAMERA

PHILLIPS

ASSEMBLY

SCREW

Figure 1. Removing Camera Module

3.Outdoor Installation – Refer to Figure 2 and select the mounting pattern: fixed or adjustable. Use the watertight mounting plate as a template and mark the fastener hole positions on the mounting surface. Prepare the holes for the fasteners.

Indoor Installation – Refer to Figure 2 and select the mounting pattern: fixed or adjustable. Use the base of the ICS200 as a template and mark the fastener hole positions on the mounting surface. Prepare the holes for the fasteners.

NOTE: The watertight mounting plate is not required for indoor installations.

FIXED MOUNTING

PATTERN

ADJUSTABLE

MOUNTING

PATTERN

Figure 2. Mounting Patterns (Watertight Mounting Plate Shown)