SWITCH SETTINGS FOR VARIFOCAL LENS

SWITCH SETTINGS FOR VARIFOCAL LENS

The high resolution camera with varifocal lens and auto iris is configured at the factory for optimal performance in lighting conditions where auto iris is required. It is also configured with the shutter speed set at 1/60 (NTSC) or 1/50 (PAL) and AGC set at

AE FunctionsTo enable automatic exposure

1AWB Automatic white balance

2 GAM Gamma function

3

AGC

Automatic gain control

4

ESC

Electronic shutter control

5

BLC

Backlight compensation

6

FL

Flickerless

7

AE

Automatic exposure

8

Not used

FACTORY SETTINGS

1 2 3 4 5 6 7 8

OFF

To manually set and lock AWB = SWITCH POSITION

6 dB of gain.

Figure 17. Switch Settings for Varifocal Lens

To enable automatic exposure

Turn on switch 7, and then turn on/off switch 4 for electronic shutter control, switch 5 for backlight compensation, and switch 6 for flickerless motion.

To manually set and lock AWB

Place a white background in front of camera and turn off switch 1.

For gamma correction

Switch to accurately reproduce scene brightness; when turned on, y = 0.6, and when turned off, y = 1.0.

For gain control

Switch 3 On increases gain by 6 dB, and switch 3 Off increases gain by 18 dB.

To enable auto iris and manually set shutter speed

Turn off switch 7; set switches 4, 5, and 6 for the desired shutter speed.

CAUTION Do not change the shutter speed unless you understand how changing the settings will affect the scene detail.

Shutter

 

Switch Number and Position

Speed

7

6

5

4

1/60 (NTSC)

 

 

On

On

On

 

 

1/50 (PAL)

 

 

 

 

 

 

 

1/100

 

 

Off

On

On

1/250

 

 

On

Off

On

1/500

 

 

Off

Off

On

 

Off

1/1000

 

 

On

On

Off

1/2000

 

 

Off

On

Off

1/4000

 

 

On

Off

Off

1/10000

 

 

Off

Off

Off

 

 

Figure 18. Varifocal Lens Shutter Speed Settings