REINSTALL CAMERA MODULE

REINSTALL CAMERA MODULE

1.Reinstall the camera module. Refer to Figure 8. Make sure the top of the camera is oriented properly. On the lens housing, look for the label that says TOP.

WARNING: To prevent damage to the camera or lens, the camera must be installed in the proper hole of the mounting bracket. If the camera is not installed in the correct hole, the window of the enclosure may be forced against the lens.

MOUNT CAMERAS WITH

 

 

 

MOUNT CAMERAS WITH

 

 

2.9 AND 3.6 MM LENSES

 

 

 

6, 8, AND 12 MM AND

 

 

 

 

VARIFOCAL LENSES

Figure 8. Camera Installation

2.Reconnect the electrical connections. If you do not need the heater, do not plug in the four-pin heater connector with red, orange, and black wires.

ADJUST POSITION

1. Turn on power to the camera and monitor.

CAUTION: Heater elements could be hot! When camera power is on, use caution when adjusting the camera. This applies to all models.

2.Varifocal Lens Only – Loosen the focal length and focus locking screws (refer to Figure 9). Adjust according to scene detail. Retighten the screws.

3.Adjust the position of the camera.

4.Adjustable Mounting Pattern Only – Refer to Figure 10. Adjust the angle of the base and tighten mounting hardware. If the watertight mounting plate is installed, remove the base, adjust the mounting plate, and reinstall the base.

VARIFOCAL LENS

LOCKING

SCREWS

Figure 9. Varifocal Lens Adjustment

REPLACE COVER

Figure 10. Adjustable Mounting Pattern

Place the cover of the ICS200 onto the base of the unit. Use the screwdriver bit (provided) and tighten the three tamperproof screws.