ADJUSTMENTS (COLOR CAMERA ONLY)
If you have a color camera, it is set up at the factory and normally requires no adjustments. Sometimes, however, adjustments may be necessary.
1.Remove the cover using the supplied
2.Adjust the vertical phase, iris level, focus, or switch settings (refer to procedures below).
3. Replace the cover.
VERTICAL PHASE
(24 VAC OPERATION ONLY)
Adjustment is required if there is vertical roll when switching between two cameras.
1.Reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem.
FIXED LENS
VERTICAL
PHASE
ADJUSTMENT
VARIFOCAL LENS
2. If reversing the connections does not solve the | VERTICAL PHASE |
problem, or if cameras are connected to different | ADJUSTMENT |
transformers, turn the adjustment screw on one |
|
camera (while switching as rapidly as possible |
|
between the two camera views) until the |
|
switching is clean and there is no vertical roll. If |
|
more than two cameras are out of synchronization |
|
with each other, choose one camera and |
|
synchronize all others to it. | Figure 11. Vertical Phase Adjustment |
AUTO IRIS LEVEL ADJUSTMENT
If you have a varifocal lens or fixed focal length lens with an auto iris, you can adjust the iris level setting to increase or decrease brightness.
VARIFOCAL LENS | FIXED LENS |
IRIS LEVEL
ADJUSTMENT
AUTO IRIS LEVEL
ADJUSTMENT
Figure 12. Iris Level Adjustment
8 |