Pelco C2406M-F (4/04) manual Adjustments Color Camera Only, VERTICAL PHASE 24 VAC OPERATION ONLY

Models: C2406M-F (4/04)

1 16
Download 16 pages 2.48 Kb
Page 8
Image 8
ADJUSTMENTS (COLOR CAMERA ONLY)

ADJUSTMENTS (COLOR CAMERA ONLY)

If you have a color camera, it is set up at the factory and normally requires no adjustments. Sometimes, however, adjustments may be necessary.

1.Remove the cover using the supplied 1/8-inch hollow screwdriver bit.

2.Adjust the vertical phase, iris level, focus, or switch settings (refer to procedures below).

3. Replace the cover.

VERTICAL PHASE

(24 VAC OPERATION ONLY)

Adjustment is required if there is vertical roll when switching between two cameras.

1.Reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem.

FIXED LENS

VERTICAL PHASE VERTICAL

PHASE

ADJUSTMENT

VARIFOCAL LENS

2. If reversing the connections does not solve the

VERTICAL PHASE

problem, or if cameras are connected to different

ADJUSTMENT

transformers, turn the adjustment screw on one

 

camera (while switching as rapidly as possible

 

between the two camera views) until the

 

switching is clean and there is no vertical roll. If

 

more than two cameras are out of synchronization

 

with each other, choose one camera and

 

synchronize all others to it.

Figure 11. Vertical Phase Adjustment

AUTO IRIS LEVEL ADJUSTMENT

If you have a varifocal lens or fixed focal length lens with an auto iris, you can adjust the iris level setting to increase or decrease brightness.

VARIFOCAL LENS

FIXED LENS

IRIS LEVEL

ADJUSTMENT

AUTO IRIS LEVEL ADJUSTMENTManual background AUTO IRIS LEVEL

ADJUSTMENT

Figure 12. Iris Level Adjustment

8

C2406M-F (4/04)

Page 8
Image 8
Pelco C2406M-F (4/04) Adjustments Color Camera Only, VERTICAL PHASE 24 VAC OPERATION ONLY, Auto Iris Level Adjustment