INSTALL BASE

INSTALL BASE

WITHOUT CONDUIT

1.Outdoor Installation Only – Bring the power and video wiring for the camera through the wiring hole in the watertight mounting plate. Then fasten the mounting plate to the mounting surface with #8 stainless steel screws (not provided) of the appropriate length.

2.Connect power input wires to the wires in the base of the Camclosure.

24 VAC – Connect power to the red and blue wires. 12 VDC – a. Connect +12 VDC to the red wire and ground to the black wire.

b.Reset the voltage jumper on the camera power board. Refer to Figure 3. Remove the jumper from JP1 (AC) and reinstall the jumper on JP2 (DC).

FOUR-PIN WITHOUT CONDUIT

POWER

CONNECTOR

24 VAC WITH CONDUIT

12 VDC

Figure 3. Voltage Jumper Settings

3.Connect the video cable. Make sure the boot covers the BNC connectors.

4.Push the power wires and video cable back through the mounting surface. Line up the mounting holes in the base with the mounting holes on the mounting surface, and attach the base as follows:

If you are attaching the base to the watertight mounting plate, use the three 10-32 x 0.625-inch screws and lock washers that are provided.

If you are fastening the base directly to a wall or ceiling, use appropriate hardware (not supplied). Use 1/4-20 hex head bolts with wall anchors in high-vandalism installations.

WITH CONDUIT

1.Outdoor Installation Only – Insert the hole plug that is supplied into the large hole in the water-tight mounting plate (refer to Figure 4). Then fasten the mounting plate to the mounting surface with #10 stainless steel screws (not provided) of the appropriate length.

HOLE PLUG Manual background

WATERTIGHT

MOUNTING PLATE

Figure 4. Install Hole Plug

2. Using a blunt tool push out the wiring plug in the

C2406M-F (4/04)