Cornelius Liquid Base Beverage Dispenser Countertop Hole Location Tubing Access

Models: Liquid Base Beverage Dispenser

1 14
Download 14 pages 54.48 Kb
Page 5
Image 5
COUNTERTOP HOLE LOCATION (TUBING ACCESS)

COUNTERTOP HOLE LOCATION (TUBING ACCESS)

1.Using the template provided, layout the location of the access hole.

2.Cut the access hole in the counter. Be sure there are no sharp edges to damage the tubing.

3.Move the Unit into position over the hole and attach the tower to the counter.

4.Route all tubing (concentrate, water, coolant and drain) through the access in the countertop.

MAKING WATER, CONCENTRATE, AND ELECTRICAL CONNECTIONS

Make Water Connections as follows:

CAUTION: If water source exceeds 65 psig a water pressure regulator kit must be used to ensure correct Unit operation. Refer to Installation Kits paragraph for part number.

CAUTION: Do not use a saw to cut tubing, use a tubing cutter or knife to avoid contamination of tubing with particles of material.

CAUTION: Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and maintained according to federal, state, and local laws.

1.Check water pressure. If water pressure is greater than 65 psig, install a water pressure regulator. Regu- late the water pressure to 50 psig.

2.Connect tubing marked “Water” to water source, but do not turn-on at this time. Additional tubing may have to be added to the existing water tubing from the dispenser.

3.If additional tubing is used, flush the tubing thoroughly by running four gallons (15 liters) of water to a drain or suitable container.

4.Connect to the tower water tubing.

5.Turn on the water supply and check for leaks.

COOLANT CONNECTION FOR HEAT EXCHANGER

Note: The inlet and outlet fittings on the Heat Exchanger are 1/2I. Use 1/2I tubing from the existing python to the Heat Exchanger. The tubing connections must be leak checked and then insulated to prevent condensation. Tubing, fittings, clamps and insulation to be supplied by the installer.

1.Select best location to tap into existing recirculating cold carbonated water tubing in the soft drink python.

2.The soft drink system must be shut down and all pressure relieved from the carbonator and associated carbonated water tubing.

3.Python insulation must be opened to permit access to the tubing.

4.Find the recirculating cold carbonated water line from the cooling unit.

5.Cut the cold carbonated water line and remove approximately 3I of the tubing to permit the installation of the elbows.

6.Connect tubing as shown in Figure 1.

3

630460001

Page 5
Image 5
Cornelius Liquid Base Beverage Dispenser Countertop Hole Location Tubing Access, Coolant Connection For Heat Exchanger