CSBDSETSAND RECEPTACLES

Useonty high quality, welPinsulated, grounded extension cords with the generator's120 Volt electrical receptacles. Inspectextension cords before each use.

Checkthe ratings of aii extension cords before you use them. Extensioncord sets used should be rated for 125Voit AC

loads at 20 Amps or greater for most electrical devices. Some devices,however, may not require this type of extension cord. Checkthe operator'smanuals of those devices for the manufacturer'srecommendations.

Keepextension cords as short as possible, preferably Iess than 15 feet iong, to prevent voltage drop and possible overheating of wires.

128 Volt AC, 28 Amp, #uplex Receptacles

Eachduplex receptacle is protected against overload by a double pole rocker switch circuit breaker.

WARNING

Overloadedelectrical cords can overheat, arc, and burn resulting in death, bodily injury, and/or property damage.

*ONLYusecordsratedfor your loads. o Followallsafetiesonebctricalcords.

128/248 VeJt AC, 38 Amp, Locking Receptacle

Usea NEMAL14-30 piug with this receptacle. Connecta

4-wire cord set rated for 250 Voit AC ioads at 30 Amps (or

greater). You can usethe same4-wire cord if you plan to run a 120 Volt load.

4-WheCordSet

J

(Neutral)

Useeach receptacieto operate 120 Volt AC,singb-phase, 60 Hzelectrical loads requiring upto 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater).

BENERAT{)RADAPTER CORD SET

The generator comes with a 25'generator adapter cord set designedto provide two sets of 120 Voit, 20 Amp outiets from one 120 Volt, 20 Amp dupiex receptacle.

Y (Hot)

X (Hot)

NEMAL14-30

/-7L7

Ground(Green)

This receptaclepowers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 5,600 watts of power (5.6 kW) at

23.3Amps for 240 Volts or two independent 120 Voit ioads at 23.3 Amps each. The outbt is protected by a double pole rocker switch circuit breaker.

NOTICE

Receptaclesmay be marked with rating vaiue greater than generator output capacity.

NEVERattemptto poweradevicerequiringrnoreamperage than generatoror receptaclecansupply,

DONOToverloadthe generator,SeeDon't OverloadGenerato,_

The maximum load on each outtet is 20 Amps. The maximum totai ioad on both biack wire outiets or white stripe wire outiets is 20 Amps.

NOTE:Foliowaii safety precautions when connecting any extension cord or deviceto the generator.