6.After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled.

Air Compressor Pump Intake and Exhaust Valves

Once a year have a Trained Service Technician check the air compressor pump intake and exhaust valves.

Motor

The motor has an automatic reset thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. The compressor will automatically restart after the motor cools.

If the overload protector shuts the motor off frequently, check for a pos- sible voltage problem. Low voltage can also be suspected when:

1.The motor does not get up to full power or speed.

2.Fuses blow out when starting the motor; lights dim and remain dim when motor is started and is running.

D28071

16- ENG

Page 16
Image 16
Craftsman 919.167461 owner manual Air Compressor Pump Intake and Exhaust Valves, Motor