PROBLEM

CAUSE

CORRECTION

Motor will not

Motor overload protection

Let motor cool off and over-

run.

switch has tripped.

load switch will automatically

 

 

reset.

 

Tank pressure exceeds

Motor will start automatically

 

pressure switch "cut-in"

when tank pressure drops

 

pressure.

below "cut-in" pressure of

 

 

pressure switch.

 

Check valve stuck open.

Remove and clean, or replace.

 

Loose electrical connec-

Check wiring connection

 

tions.

inside pressure switch and ter-

 

 

minal box area.

 

Possible defective motor

Have checked by a Trained

 

or starting capacitor.

Service Technician.

 

Paint spray on internal

Have checked by a Trained

 

motor parts.

Service Technician. Do not

 

 

operate the compressor in the

 

 

paint spray area. See flamma-

 

 

ble vapor warning.

 

Pressure release valve on

Bleed the line by pushing the

 

pressure switch has not

lever on the pressure switch to

 

unloaded head pressure.

the "off" position; if the valve

 

 

does not open, replace switch.

 

Fuse blown, circuit breaker

1. Check fuse box for blown

 

tripped.

fuse and replace as nec-

 

 

essary. Reset circuit

 

 

breaker. Do not use a fuse

 

 

or circuit breaker with

 

 

higher rating than that

 

 

specified for your particu-

 

 

lar branch circuit.

 

 

2. Check for proper fuse. You

 

 

should use a time delay

 

 

fuse.

 

 

3. Check for low voltage

 

 

conditions and/or proper

 

 

extension cord.

 

 

4. Disconnect the other elec-

 

 

trical appliances from cir-

 

 

cuit or operate the com-

 

 

pressor on its own branch

 

 

circuit.

Knocking Noise.

Possible defect in safety

Operate safety valve manually

 

valve.

by pulling on ring. If valve still

 

 

leaks, it should be replaced.

 

Defective check valve.

Remove and clean, or replace.

 

 

 

21- ENG

D28071

Page 21
Image 21
Craftsman 919.167461 owner manual Minal box area