MAINTENANCE

Customer Responsibilities

 

Before

Daily or

 

 

 

 

each

after

 

Frequently

Yearly

 

each

 

 

use

 

 

 

 

use

 

 

 

 

 

 

 

 

Check Safety Valve

 

 

 

 

Drain Tank

 

 

 

 

Air Filter

 

 

 

● (1)

 

Air compressor pump intake

 

 

 

 

and exhaust valves

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1- more frequent in dusty or humid conditions

 

 

 

 

 

 

 

 

Risk of Unsafe

Operation. Unit

cycles automatically when power is on. When servicing, you may be exposed to voltage sources, com- pressed air, or moving parts. Before servicing unit unplug or dis- connect electrical supply to the air compressor, bleed tank of pres- sure, and allow the air compressor to cool.

To ensure efficient operation and longer life of the air compressor unit, a routine maintenance schedule should be prepared and followed. The following routine maintenance schedule is geared to an unit in a normal working environment operat- ing on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your compressor is used. The modifica- tions will depend upon the hours of operation and the working environ- ment. Compressor units in an extremely dirty and/or hostile environ- ment will require a greater frequency of all maintenance checks.

To Check Safety Valve

Risk of Bursting. If the safety valve

does not work properly, over- pressurization may occur, causing air tank rupture or an explosion.

1.Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.

To Drain Tank

1.Set the On/Auto/Off lever to “OFF” and unplug unit.

2.Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero.

3.Remove the air tool or accesso- ry.

4.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

5.Drain water from air tank by opening drain valve (counter- clockwise) on bottom of tank.

Risk of Bursting. Water will con-

dense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

15- ENG

D28071

Page 15
Image 15