2.If only one cleaning solution is being used both tanks may be filled with the same solution to double the capacity before refilling tanks.

3.If only one cleaning solution is being used the second tank may be filled with clean water to conveniently rinse the chemical injector after use.

TO SHUT DOWN

IMPORTANT: Read and understand how to shut down the pressure washer before operating.

1.After use of cleaning solution the chemical injector MUST be rinsed in order to prevent pump damage caused by solution build up. The warranty will not cover pumps that are damaged because the chemical injector was not properly rinsed.

To rinse chemical injector using chemical injector rinsing hose

a.Remove cleaning solution hose from chemical injector barb fitting.

b.Push chemical injector rinsing hose onto the chemical injector barbed fitting.

c.Place other end of chemical injector rinsing hose into container of clean water and depress trigger to draw at least one gallon of clean water through chemical injection system to rinse system thoroughly.

d.Before reconnecting cleaning solution hose to chemical injector barb fitting make sure that any remaining cleaning solution has been completely drained from the cleaning

solution hose.

To rinse chemical using cleaning solution system tank

a.Turn control valve knob arrow to the down (off) position.

Control Valve Knob

b.Fill one of the cleaning solution system tanks with clean water.

c.Turn control valve knob toward tank with clean water.

Tank to be used

d.Depress trigger to draw clean water through chemical injection system to rinse system thoroughly.

2.Turn engine off by placing the throttle control in the OFF position.

NOTE: NEVER turn the water off with the engine running.