DigitalMedia Room Controller Crestron DM-RMC-100
Metal mounting plate (supplied)
4-Pin connector plugs (supplied)
It is assumed that DigitalMedia cable (DM-CBL) has been fed through an
installed two-gang electrical box, 85mm European or 1900 electrical box
(not supplied) and wiring has been verified. Use the following procedure
to install the DM-RMC-100.
1. Confirm that DMNet system power is OFF.
2. Attach supplied connector plugs according to the pinout on pages 8
and 9.
3. Attach metal mounting plate to electrical box using two Phillips
screws (not supplied).
4. Make DM-INPUT connections using DM-CBL.
Connect the RJ-45 terminated blue shielded DigitalMedia cable
to the DM-INPUT D port.
Connect the yellow RJ-45 terminated CAT5e/CAT6 cable to
the DM-INPUT M port.
Connect the DMNet cable with the supplied connector plug to
the DM-RMC-100’s 24 A B G port.
5. Make the LAN connection to the DM-RMC-100’s LAN port using
an Ethernet cable with an RJ-45 connector.
6. Attach DM-RMC-100 to mounting plate using four #06-32 x 1/4"
Phillips screws (supplied) as shown in illustration on the following
page.
12 DigitalMedia Room Controller: DM-RMC-100 Operations & Installation – DOC. 6743A