Uploading and Upgrading
Crestron recommends using the latest programming software and that
each device contains the latest firmware to take advantage of the most
recently released features. However, before attempting to upload or
upgrade it is necessary to establish communication. Once communication
has been established, files (for example, firmware) can be transferred to
the device.
Establishing Communication
Use Crestron ToolboxTM for communicating with the DM-RMC-100;
refer to the Crestron Toolbox help file for details. There is a single
method of communication: indirect communication.
Indirect Communication
SERIAL,
ETHERNET
OR USB
DMNet
PC RUNNING
CRESTRON TOOLBOX DM SWITCHER DM-RMC-100
• DM-RMC-100 connects to a DigitalMedia™ switcher via DMNet.
• Establish communication between the PC and the DM switcher
as described in the latest version of a DigitalMedia Switcher
Operations Guide (Doc. 6755).
• Use the Address Book in Crestron Toolbox to create an entry for
the DM-RMC-100 using the expected communication protocol
(Indirect). Select the Cresnet ID of the DM-RMC-100 and the
address book entry of the control system or DM Switcher that is
connected to the DM-RMC-100.
• Display the DM-RMC-100’s “System Info” window (click the
icon); communications are confirmed when the device
information is displayed.