4 Advanced Operation
Low Limit Load Errors: This screen lets you view
When an error occurs, the count displayed in this screen is incremented, and the operating time since the error is displayed.
To clear this screen, press and release an Encoder. The display will prompt you to confi rm your choice by pressing and holding the Encoder.
NOTE: You must use System Architect to enable error reporting and set its limits.
Low Limit Load Errors
0 0
0.0 Hrs Last 0.0 Hrs
High Limit Load Errors: This screen lets you view high limit load errors without using the control software. A high limit load error occurs if the load impedance rises above the value set with the High Limit value on the software Control Panel.
When an error occurs, the count displayed in this screen is incremented, and the operating time since the error is displayed.
To clear this screen, press and release an Encoder. The display will prompt you to confi rm your choice by pressing and holding the Encoder.
NOTE: You must use System Architect to enable error reporting and set its limits.
High Limit Load Errors
0 0
0.0 Hrs Last 0.0 Hrs
Operation Manual
SLM (Sweep Load Monitoring) Errors: This screen lets you view SLM errors without using the control software.
When an error occurs, the count displayed in this screen is incremented, and the operating time since the error is displayed.
To clear this screen, press and release an Encoder. The display will prompt you to confi rm your choice by pressing and holding the Encoder.
NOTE: You must use System Architect to enable error reporting and set its limits.
SLM Errors
0 0
0.0 Hrs Last 0.0 Hrs
Line Voltage Errors: This screen lets you view
When an error occurs, the count displayed in this screen is incremented, and the operating time since the error is displayed. The “Low” and “High” indicators show whether the line voltage was below or above the
To clear this screen, press and release an Encoder. The display will prompt you to confi rm your choice by pressing and holding the Encoder.
NOTE: You must use System Architect to enable error reporting and set its limits.
Line Voltage Errors
0Low | High0 |
0.0 Hrs Last | 0.0 Hrs |
Fan Errors: When a fan error occurs, the count displayed in this screen is incremented, and the operating time since the error is displayed.
Fan Errors
0
0.0 Hrs Last
Clear All Error Logs: In this screen, you can press and hold an Encoder knob to clear all the error logs.
Clear All Error Logs
Press and hold enc.
to clear ALL error logs
Exit: To exit the Alert Menu and go to the Attenuation screen, press Menu/Exit once.
4.2.6 NETWORKING MENU
To access this menu from the Attenuation screen, press an Encoder knob, then press Prev twice. This menu has screens for setting up audio network parameters. Push an Encoder knob to see the selections in the Networking Menu.
Networking Menu
Networking Menu
Push knob for net. menu
Network Info: This screen displays information about the audio network: IP address, HiQnet address, Subnet and MAC address. Section 9.1 of this manual explains these terms.
Network Info
IP:192.168.1.1 HiQNet:1
SUBNET:255.255.0.0
MAC: 00:0A:40:00:E4:C2
Manufacturing Info: This screen displays information about your
amplifi er: model number, fi rmware version, serial number, and amplifi er date code.
Manufacturing Info
IT90000HD | FW Ver:1.0.0.6 |
S/N:8001576436
Amp Mfg
HiQnet Node Address: This screen lets you set the HiQnet address of this amplifi er (a node in the network). Turn an Encoder knob to set the address, then press the knob to save your setting.
HiQnet Node Addr
32
Turn to
page 21