4 Advanced Operation
4.8.14 Amplifier Information
Information about the amplifi er is stored in the software system inventory and is displayed on the software control panels. Information includes manufacturer, model, date code, and serial number. The green items can’t be edited.
Channel Labels: Each amplifi er includes two labels that you may edit for your own use. Simply type in the text areas. Use these labels to describe the channels of your amplifi er. These names will appear in the individual processing blocks.
Attenuator Limits: This lets you set a limit on the attenuators. You can set the maximum attenuation from 0 dB to
NOTE: The attenuator setting must be below the attenuator limit that you are trying to set. For example, if the attenuator is set at
Blackout Mode: This button lets you blackout the front panel display until you press a
4.8.15 Apply to Others
This screen lets you apply the System Architect settings for your
4.8.16 Delay (Latency)
Due to the nature of DSP processing, there is some inherent delay or latency within the
Table 4. I-Tech HD latencies at two sample rates
Sample | ADC | DSP | DAC | Ampli- | Total |
rate |
|
|
| fier | latency |
|
|
|
|
|
|
48 kHz | 250µs | 666µs | 196µs | 54µs | 1.166ms |
|
|
|
|
|
|
96 kHz | 94µs | 333µs | 48µs | 54µs | 529µs |
|
|
|
|
|
|
These latencies do not include CobraNet Transport Latency and FIR Processing Latency.
Operation Manual | page 35 |