Operating Your Outdoor Grill

Lighting the Burners (Continued)

Manual Lighting Procedures - Grill Compartment

warning

Use the manual lighting procedure only in the event that one or more of the igniters is not working:

Use only the Dacor supplied match light tool or a long stemmed match.

Do not attempt to light the optional sear burner without the grate above it in place. Do not attempt to light the standard burners without the flame spreaders in place.

Make sure all control knobs are in the OFF position before performing the manual lighting procedure.

If a flame that has been lit manually goes out, immediately turn the control knob to the OFF position to avoid a fire or explosion hazard. Allow five minutes for gas to dissipate before re-lighting it.

To manually light the rotisserie burner, see page 14.To manually light the standard U shaped burners:

1.Make sure the drip tray is in place.

2.Make sure all control knobs are in the OFF position.

3.Open the canopy and remove all of the grates above the standard burners. If the appliance is equipped with the optional sear burner, leave the grate above it in place.

4.If using a LP tank, turn the valve on the top of the tank, counter-clockwise, to the fully open position.

5.Find the lighting hole in the front of the flame spreader located directly behind the front control panel for the burner you intend to light.

6.Use the provided match holder or a long stem match to light the burner manually. Push in on the control knob and turn it counter-clockwise while inserting a lit match into the lighting hole. If you do not experience immediate ignition, turn the knob back to the OFF position. Leave the

canopy open and waitfive minutes. Repeat

the lighting procedure. Lighting hole

7. If the burner does not light after two tries, see the Before You Call for Service section on page 23.

To manually light the optional sear burner:

1.Make sure the drip tray is in place.

2.Make sure all control knobs are in the OFF position.

3.Make sure the grate above the sear burner is in place.

4.If using a LP tank, turn the valve on the top of the tank, counter-clockwise, to the fully open position.

5.Use the provided match holder or a long stem match to light the burner manually. Insert a lit match at an angle through the grate above the sear burner. While keeping the lit end of the match a little above the surface of the sear burner, push in on the control knob and turn it counter-clockwise. If you do not experi- ence immediate ignition, turn the knob back to the OFF position. Leave the canopy open and wait five minutes. Repeat the lighting procedure.

Sear burner

6.If the burner does not light after two tries, see the Before You Call for Service section on page 23.

To manually light one of the optional sear burners:

1.Make sure the drip tray is in place.

2.Make sure all control knobs are in the OFF position.

3.If using a LP tank, turn the valve on the top of the tank, counter-clockwise, to the fully open position.

4.Use the provided match holder or a long stem match to light the burner manually. With the end of the lit match next to the burner holes, push in on the cor- responding control knob and turn it counter-clockwise.

If you do not experience immediate ignition, turn the knob back to the OFF position. Wait five minutes, and repeat the lighting procedure.

5.If the burner does not light after two tries, see the Before You Call for Service section on page 23.

12