6.To remove high voltage capacitor.
1)Remove a screw which secure the grounding ring terminal of the H.V. diode and the capacitor holder.
2)Remove the H.V. diode from the capacitor holder.
3) Reverse the above steps for reassembly.
◆High voltage circuit wiring
7. To remove magnetron.
1) Remove a screw which secure the magnetron.
2) Remove the magnetron.
3) Reverse the above steps for reassembly.
NOTE : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to pre- vent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave leakage. It shall not exceed 4mW/cm2 for a fully assembled oven with door normally closed.
Metallic
gasket
plate
Magnetron antenna
Cooling fin
Filament terminal
<MAGNETRON>
14