Daewoo KOR-6Q2B5S service manual Interlock Mechanism And Adjustment

Models: KOR-6Q2B5S

1 33
Download 33 pages 52.46 Kb
Page 17
Image 17
INTERLOCK MECHANISM AND ADJUSTMENT

INTERLOCK MECHANISM AND ADJUSTMENT

The door lock mechanism is a device which has been specially designed to completely eliminate microwave radiation when the door is opened during operation, and thus to perfectly prevent the danger resulting from the leakage of microwave.

(1)Primary interlock switch

When the door is closed, the hook locks the oven door. If the door is not closed properly, the oven will not operate. When the door is closed, the hook pushes the button of the microswitch. Then the button of the primary interlock switch bring it under NO condition.

(2)Secondary interlock switch and interlock monitor switch

When the door is closed, the hook pushes the lock lever downward. The lock lever presses the button of the interlock monitor switch to bring it under NO condition and presses the button of the secondary interlock switch to bring it under NO condition.

ADJUSTMENT :

Interlock monitor switch

When the door is closed, the interlock monitor switch should be changed (NO condition) before other switches are closed. When the door is opened, the interlock monitor switch should be changed (NC condition) after other switches are opened.

(3)Adjustment steps

a)Loosen the mounting screw.

b)Adjust interlock switch assembly position.

c)Make sure that lock lever moves smoothly after adjustment is completed.

d)Tighten completely a mounting screw.

NOTE :

Microwave emission test should be performed after adjusting interlock mechanism. If the microwave emission exceed 4mW/cm2, readjust interlock mechanism.

16

Page 17
Image 17
Daewoo KOR-6Q2B5S service manual Interlock Mechanism And Adjustment