FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 3: INSTALLATION
3.2Gas Connections (cont.)
I.Flexible Couplings, Connectors and Casters:
1.If the fryer is to be installed with flexible couplings and/or
WARNING
Do not attach accessories to this fryer unless fryer is secured from tipping.
Personal injury may result.
2.The fryer must be restrained by means independent of the flexible coupling or connector in order to limit the movement of the fryer. Clips are located on the back panel of the fryer for the attachment of restraints.
3.If disconnection of the restraint is necessary, this restraint must be reconnected after the fryer has been returned to its originally installed position.
J.After
3.3Adjustments/Adaptation To Different Gases
A.Proper operation of Frymaster/Dean gas fryers requires operator to inspect the following adjustments in terms of:
1.Gas inputs and pressures.
2.Voltage and polarities of electrical power supplies.
B.Frymaster/Dean gas fryers are manufactured to use the type of gas and pressure specified on the rating plate. When changing to a different gas, adaptation must be performed by qualified personnel. Failure to use qualified personnel will void the Frymaster/Dean warranty.