Frymaster FDP65 operation manual Frymaster FPD65 Series GAS Fryers Filtration Operation

Models: FDP65

1 60
Download 60 pages 24.42 Kb
Page 36
Image 36

FRYMASTER FPD65 SERIES GAS FRYERS

CHAPTER 5: FILTRATION OPERATION

5.4.1 Filter Operation (cont.)

8.Begin the filtering process by pulling the yellow handle to open the oil-return valve (this activates the filter pump automatically).

Begin the filtering process by pulling yellow handle to open oil return valve. Leave the drain valve (red handle) open during the filtering process.

9.Oil will begin to pump from the filter pan into the frypot. Allow the oil to circulate through the frypot for the remainder of the timed countdown (approximately 10 minutes). This process is known as "polishing".

Polishing the oil removes suspended particles, which increases the life of the oil.

10.The computer will display FILL at the end of the timed countdown. Replace the frypot grid rack. Close the red drain valve handle to begin refilling the frypot.

When the computer displays FILL, close the drain valve to begin refilling the frypot.

5-9

Page 36
Image 36
Frymaster FDP65 operation manual Frymaster FPD65 Series GAS Fryers Filtration Operation