Daewoo KOR-6Q2B5S Printed Circuit Board, Circuit Check Procedure, Low Voltage Transformer check

Models: KOR-6Q2B5S

1 33
Download 33 pages 52.46 Kb
Page 26
Image 26
PRINTED CIRCUIT BOARD

PRINTED CIRCUIT BOARD

1. CIRCUIT CHECK PROCEDURE

1. Low Voltage Transformer check

1. CIRCUIT CHECK PROCEDURE The low voltage transformer is located on the P.C.B.

1. Low Voltage Transformer check Measuring condition: input voltage : 230V/Frequency : 50Hz

Terminal Voltage

LOAD

 

NO LOAD

 

 

 

 

5-6-7

AC 12.6

V

AC 14.7 V

NOTE :

1.Refer to Circuit Diagram (point 4).

2.Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source voltage.

3.The allowable tolerance of the secondary voltage is within 2.Voltage check5% of nominal voltage.

2.Voltage check

CHECK POINT Key check point

NO

CHECK POINT

REMARK

1

IC 1 PIN 5

5 VDC

 

 

 

2

IC 1 PIN 8

 

T:20ms(50Hz)

3

IC 1 PIN 35 OR PIN 36

T:250ns(4MHz)

MEASURE POINT Check method

NO

MEASURE POINT
WAVE FORM
REMEDY

REMARK

 

 

 

 

 

 

1

MP1

DC

5V 0.25V

Replace VL1, EC1

NO LOAD

 

 

 

 

 

 

2

MP2

DC

12V 2.0V

Replace EC2, D11, D13, D14

NO LOAD

 

 

 

 

 

 

NOTE :

Each measure point must be measured with GND point.

25

Page 26
Image 26