dCS Verona User Manual

Manual for Software Issue 1.0x

dCS Ltd

September 2004

 

 

MAINTENANCE AND SUPPORT

Service & Maintenance

Mains Fuse

IMPORTANT!

dCS audio products are designed not to need regular maintenance, and contain no user serviceable parts apart from the mains fuse.

If your unit is damaged in some way, please contact your dealer or dCS.

There is a mains fuse below the power inlet, accessible from the outside of the unit. If the fuse blows, it may be changed by the user. The current consumption of the unit is very low, so it only blows if power surges occur, or there is a fault in the unit. Usually, power surges cause no other damage, but if the fuse blows repeatedly on replacement, some other damage will have been done and the unit must be returned to dCS for repair.

Fuse Type: 20 x 5mm 0.5 amp T HRC fuse

If the fuse should fail, it is essential that it be replaced with one of the same type and rating. Failure to do so could result in damage to the unit, risk of fire or electric shock and will invalidate the guarantee.

Replacing a Blown Fuse

x

Referring to Figure 7, remove the power cable, use a small flat bladed screwdriver to pry up the tab on the fuse carrier (A) and pull it out. Push the blown fuse out of the clip in the carrier (B) and dispose of it. Fit a new fuse in the clip (C) and push the carrier back into the unit so that it clicks home. Spare fuses are provided with the unit.

A

B

C

 

Figure 7 – Changing the Mains Fuse

IMPORTANT! Disconnect the power cable before changing the fuse.

Manual filename: Verona Manual v1.0x.doc

Page 32

email: more@dcsltd.co.uk

English version

 

web-site: www.dcsltd.co.uk